Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage/Application | Heating |
Connecting | 3 PASS OR 4 PASS |
Material | Mild Steel |
Size | AS PER REQUIREMENT |
Firing Mode | WOOD/ COAL/ OIL/ BRIQUETTES |
Tank Capacity | 800-2000 LITRES |
Voltage V | 415 V |
Maximum Temperature | 300 DEG C |
Country of Origin | Made in India |
CONVECTION HEAT EXCHANGER
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials.
RADIANT HEAT EXCHANGER
The coil of rediant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting.
REFRACTORY CONNECTION (DUCT)
Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire crete super and insulite 7 material
INSTRUMENTATION & SAFETY CONTROLS
• Digital electronic indicator cum controller for return temperature for ID fan cut off. Digital electronic indicator cum controller for forward temperature for ID fan cut off.
• Forward high temperature safety controller shut off the unit in case of the forward temperature exceeds maximum recommended temperature.
• Low level controller in expansion cum dearator tank shut off the unit in case of low thermic fluid level in tank.
• Pressure gauge for Inlet pressure measurement.
• Electronic stack temperature controller shuts off the unit in case of abnormally high temp. • Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
• Audio visual alarm for abnormal operating conditions. • Pressure gauge for circuit pressure measurement
Additional Information:
Approx. Rs 4 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Connecting | 3 Pass |
Material | Mild Steel |
Size | 2700mm height max |
Firing Mode | Wood/Coal |
Tank Capacity | 800 |
Voltage V | 415 V |
Maximum Temperature | 300 |
Country of Origin | Made in India |
CONVECTION HEAT EXCHANGER
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials.
RADIANT HEAT EXCHANGER
The coil of rediant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting.
REFRACTORY CONNECTION (DUCT)
Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire crete super and insulite 7 material
INSTRUMENTATION & SAFETY CONTROLS
• Digital electronic indicator cum controller for return temperature for ID fan cut off. Digital electronic indicator cum controller for forward temperature for ID fan cut off.
• Forward high temperature safety controller shut off the unit in case of the forward temperature exceeds maximum recommended temperature.
• Low level controller in expansion cum dearator tank shut off the unit in case of low thermic fluid level in tank.
• Pressure gauge for Inlet pressure measurement.
• Electronic stack temperature controller shuts off the unit in case of abnormally high temp. • Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
• Audio visual alarm for abnormal operating conditions. • Pressure gauge for circuit pressure measurement
Additional Information:
Approx. Rs 10 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage/Application | Heating |
Connecting | 3 PASS |
Material | Mild Steel |
Firing Mode | SOLID FUEL |
Tank Capacity | 800-2000 L |
Voltage V | 415 |
Maximum Temperature | 280 C |
Heat Output | 1 LAC KCAL/HR- 10 LAC KCAL/HR |
CONVECTION HEAT EXCHANGER
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials.
RADIANT HEAT EXCHANGER
The coil of rediant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting.
REFRACTORY CONNECTION (DUCT)
Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire crete super and insulite 7 material
INSTRUMENTATION & SAFETY CONTROLS
• Digital electronic indicator cum controller for return temperature for ID fan cut off. Digital electronic indicator cum controller for forward temperature for ID fan cut off.
• Forward high temperature safety controller shut off the unit in case of the forward temperature exceeds maximum recommended temperature.
• Low level controller in expansion cum dearator tank shut off the unit in case of low thermic fluid level in tank.
• Pressure gauge for Inlet pressure measurement.
• Electronic stack temperature controller shuts off the unit in case of abnormally high temp. • Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
• Audio visual alarm for abnormal operating conditions. • Pressure gauge for circuit pressure measurement
Additional Information:
Approx. Rs 10.8 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage/Application | Heating |
Connecting | 4 PASS |
Material | Mild Steel |
Size | 4LAC KCAL/HR-10LAC KCAL/HR |
Firing Mode | WOOD/COAL/BRIQUETTES |
Tank Capacity | 800 L-2000 L |
Voltage V | 415V |
Maximum Temperature | 300 |
CONVECTION HEAT EXCHANGER
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials.
RADIANT HEAT EXCHANGER
The coil of rediant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting.
REFRACTORY CONNECTION (DUCT)
Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire crete super and insulite 7 material
INSTRUMENTATION & SAFETY CONTROLS
• Digital electronic indicator cum controller for return temperature for ID fan cut off. Digital electronic indicator cum controller for forward temperature for ID fan cut off.
• Forward high temperature safety controller shut off the unit in case of the forward temperature exceeds maximum recommended temperature.
• Low level controller in expansion cum dearator tank shut off the unit in case of low thermic fluid level in tank.
• Pressure gauge for Inlet pressure measurement.
• Electronic stack temperature controller shuts off the unit in case of abnormally high temp. • Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
• Audio visual alarm for abnormal operating conditions. • Pressure gauge for circuit pressure measurement
Additional Information:
Approx. Rs 3.1 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Connecting | 3 PASS |
Material | Mild Steel |
Size | Approx 2.6mtr height |
Firing Mode | COAL/WOOD |
Voltage V | 415 V |
Maximum Temperature | 300 deg C |
We are the well-known organizations, engaged in offering a precisely engineered range of Wood Fired Thermic Fluid Heater. The offered heater is manufactured using high grade raw material and cutting-edge technology. This heater is used for heating various types of material in various industries. Further, this heater is suitable for coal, wood, briquette, husk, agro waste, etc. We provide this heater in various capacities as per the specific requirements of clients.
Features:
Excellent performance
Easy installation
Longer service life
Specifications:
Capacity:-Range Starts 50000 kcal/hr. to 50, 00,000 kcal/hr.
Fuel:-Solid Fuels, Wood, Husk, Coal, Lignite, Agro Waste, Pat Coak.
Solid Fuel Fired Four Pass Thermopack The Shree Engineers solid fired thermopac system is forced circulation and automatic thermic fluid heater in liquid phase. In the system thermic fluid is circulated and heated up to 300° C and re-circulated to dissipate heat into the process. The combined expansion cum deaerator tank ensures the system vapor less and pressure less.
Radiant heat exchanger
Convective heat exchanger convection heat exchanger
Furnace
Ash settling chamber
F. D. Fan
D. Fan
Air pre-heater
Mechanical dust collector
Refractory duct
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials RADIANT HEAT EXCHANGER The coil of radiant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting. REFRACTORY CONNECTION (DUCT) Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire create super and insulate 7 material) INSTRUMENTATION & SAFETY CONTROLS
Digital electronic indicator cum controller for return temperature for ID fan cut off.
Digital electronic indicator cum controller for forward temperature for ID fan cut off.
Forward high temperature safety controller shut off the unit in case of the forward temperature
Exceeds maximum recommended temperature.
Low level controller in expansion cum deaerator tank shut off the unit in case of low thermic fluid level in tank.
Pressure gauge for Inlet pressure measurement.
Electronic stack temperature controller shuts off the unit in case of abnormally high temp.
Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
Audio visual alarm for abnormal operating conditions.
Pressure gauge for circuit pressure measurement.
Additional Information:
Approx. Rs 13.5 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Types | Ring Heaters |
Type | 3 PASS OIL FIRED TFH |
Heating Source | BURNER |
Fuel Type | DIESEL/GAS |
Firing Mode | AUTOMATIC |
Voltage | 415 V |
CONVECTION HEAT EXCHANGER
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials.
RADIANT HEAT EXCHANGER
The coil of rediant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting.
REFRACTORY CONNECTION (DUCT)
Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire crete super and insulite 7 material
INSTRUMENTATION & SAFETY CONTROLS
• Digital electronic indicator cum controller for return temperature for ID fan cut off. Digital electronic indicator cum controller for forward temperature for ID fan cut off.
• Forward high temperature safety controller shut off the unit in case of the forward temperature exceeds maximum recommended temperature.
• Low level controller in expansion cum dearator tank shut off the unit in case of low thermic fluid level in tank.
• Pressure gauge for Inlet pressure measurement.
• Electronic stack temperature controller shuts off the unit in case of abnormally high temp. • Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
• Audio visual alarm for abnormal operating conditions. • Pressure gauge for circuit pressure measurement
Additional Information:
Approx. Rs 2 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Type | 3 PASS AND 4 PASS |
Heating Source | OIL |
Fuel Type | WOOD/COAL/OIL |
Firing Mode | MANUAL OR AUTOMATIC |
Voltage | 415 V |
Condition | New |
Size | 2400MM-2700MM |
Phase | 3 PHASE |
Capacity | 1 LAC KCAL/HR-25 LAC KCAL/HR |
Country of Origin | Made in India |
Additional Information:
Approx. Rs 5 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Connecting | 3 PASS |
Material | Mild Steel |
Size | AS PER REQUIREMENT |
Firing Mode | DIESEL OR GAS |
Tank Capacity | 800-2000 LITRES |
All Std Safety Accessories | PROVIDED |
Country of Origin | Made in India |
CONVECTION HEAT EXCHANGER
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials.
RADIANT HEAT EXCHANGER
The coil of rediant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting.
REFRACTORY CONNECTION (DUCT)
Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire crete super and insulite 7 material
INSTRUMENTATION & SAFETY CONTROLS
• Digital electronic indicator cum controller for return temperature for ID fan cut off. Digital electronic indicator cum controller for forward temperature for ID fan cut off.
• Forward high temperature safety controller shut off the unit in case of the forward temperature exceeds maximum recommended temperature.
• Low level controller in expansion cum dearator tank shut off the unit in case of low thermic fluid level in tank.
• Pressure gauge for Inlet pressure measurement.
• Electronic stack temperature controller shuts off the unit in case of abnormally high temp. • Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
• Audio visual alarm for abnormal operating conditions. • Pressure gauge for circuit pressure measurement
Additional Information:
Approx. Rs 3 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Size | As per capacity of thermic fluid heater |
Firing Mode | Solid Fuel fired |
Material | Mild Steel |
Usage/Application | Industrial |
Electric Load | As per capacity |
Tank Capacity | As per capacity |
Color | Blue |
Voltage V | 230 volt |
Country of Origin | Made in India |
CONVECTION HEAT EXCHANGER
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials.
RADIANT HEAT EXCHANGER
The coil of rediant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting.
REFRACTORY CONNECTION (DUCT)
Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire crete super and insulite 7 material
INSTRUMENTATION & SAFETY CONTROLS
• Digital electronic indicator cum controller for return temperature for ID fan cut off. Digital electronic indicator cum controller for forward temperature for ID fan cut off.
• Forward high temperature safety controller shut off the unit in case of the forward temperature exceeds maximum recommended temperature.
• Low level controller in expansion cum dearator tank shut off the unit in case of low thermic fluid level in tank.
• Pressure gauge for Inlet pressure measurement.
• Electronic stack temperature controller shuts off the unit in case of abnormally high temp. • Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
• Audio visual alarm for abnormal operating conditions. • Pressure gauge for circuit pressure measurement
Additional Information:
Approx. Rs 8 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Usage/Application | Industrial |
Connecting | 3 PASS |
Material | Mild Steel |
Size | APPROX 14 FEET HEIGHT |
Firing Mode | COAL/WOOD |
Color | BLUE AND BLACK |
Voltage V | 415 V |
Electric Load | 16.5HP |
Country of Origin | Made in India |
We are the well-known organizations, engaged in offering a precisely engineered range of Coal Fired Thermic Fluid Heater. The offered heater is manufactured using high grade raw material and cutting-edge technology. This heater is used for heating various types of material in various industries. Further, this heater is suitable for coal, wood, briquette, husk, agro waste, etc. We provide this heater in various capacities as per the specific requirements of clients.
Features:
Excellent performance
Easy installation
Longer service life
Specifications:
Capacity:-Range Starts 50000 kcal/hr. to 50, 00,000 kcal/hr.
Fuel:-Solid Fuels, Wood, Husk, Coal, Lignite, Agro Waste, Pat Coak.
Solid Fuel Fired Four Pass Thermopack The Shree Engineers solid fired thermopac system is forced circulation and automatic thermic fluid heater in liquid phase. In the system thermic fluid is circulated and heated up to 300° C and re-circulated to dissipate heat into the process. The combined expansion cum deaerator tank ensures the system vapor less and pressure less.
Radiant heat exchanger
Convective heat exchanger convection heat exchanger
Furnace
Ash settling chamber
F. D. Fan
D. Fan
Air pre-heater
Mechanical dust collector
Refractory duct
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials RADIANT HEAT EXCHANGER The coil of radiant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting. REFRACTORY CONNECTION (DUCT) Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire create super and insulate 7 material) INSTRUMENTATION & SAFETY CONTROLS
Digital electronic indicator cum controller for return temperature for ID fan cut off.
Digital electronic indicator cum controller for forward temperature for ID fan cut off.
Forward high temperature safety controller shut off the unit in case of the forward temperature
Exceeds maximum recommended temperature.
Low level controller in expansion cum deaerator tank shut off the unit in case of low thermic fluid level in tank.
Pressure gauge for Inlet pressure measurement.
Electronic stack temperature controller shuts off the unit in case of abnormally high temp.
Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
Audio visual alarm for abnormal operating conditions.
Pressure gauge for circuit pressure measurement.
Additional Information:
Approx. Rs 10.85 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage/Application | Heating |
Connecting | 4 PASS |
Material | Mild Steel |
Firing Mode | WOOD/COAL/BRIQUETTES |
Tank Capacity | 800-2000 LITRES |
Voltage V | 415V |
Maximum Temperature | 300 C |
Heat Output | 4 LAC KCAL/HR - 25 LAC KCAL/HR |
Design Thermal Efficiency | 87% ON NCV |
CONVECTION HEAT EXCHANGER
Convection zone heat exchanger is designed on coil to coil principle comprising 2 coils fabricated out of high heat resistant ERW boiler tubes. It is equipped with special fly ash collecting device. Outer surface of the heat exchanger is covered with insulating panel consisting high grade insulating materials.
RADIANT HEAT EXCHANGER
The coil of rediant heat exchanger conical shape and fabricated out of high heat resistant ERW boiler tube. It is mounted on suitable designed furnace. It is fabricated out or heavy duty material and provided with necessary fuel feeding arrangement. Furnace is constructed with high quality fire bricks and insulation bricks. The bricks wall is designed in such a way it ensures minimum heat loss. The furnace also is equipped with high heat resistant casting.
REFRACTORY CONNECTION (DUCT)
Both radiant and convection heat exchangers are connected by a specially designed refractory duct which allows flue gas pass from radiant to convection exchanger. (Made of insulating bricks, fire crete super and insulite 7 material
INSTRUMENTATION & SAFETY CONTROLS
• Digital electronic indicator cum controller for return temperature for ID fan cut off. Digital electronic indicator cum controller for forward temperature for ID fan cut off.
• Forward high temperature safety controller shut off the unit in case of the forward temperature exceeds maximum recommended temperature.
• Low level controller in expansion cum dearator tank shut off the unit in case of low thermic fluid level in tank.
• Pressure gauge for Inlet pressure measurement.
• Electronic stack temperature controller shuts off the unit in case of abnormally high temp. • Differential pressure switch shut off unit in case of abnormal thermic fluid flow condition.
• Audio visual alarm for abnormal operating conditions. • Pressure gauge for circuit pressure measurement
Additional Information: